Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. bras. crescimento desenvolv. hum ; 25(3): 292-296, 2015. tab
Article in English | LILACS | ID: lil-772558

ABSTRACT

Auditory brainstem response is a response to external stimulation that represents the neural electrophysiological activity of the auditory system at the brainstem level. Variations due to the change in the presentation of stimuli help in the diagnosis of clinical conditions that affect the auditory nervous system OBJECTIVE: To characterize and compare the different polarity variations stimuli and presentation rates in adults with normal hearing METHODS: We investigated 20 students from a Center for Diagnosis and Rehabilitation, with no hearing impairment, all female aged 15-30 years old, who were screened for brainstem auditory evoked potential, which presented stimuli in different polarities ranges, including condensation and rarefaction in different presentation rates of 21.7, 27.7 and 47.7 stimuli per second RESULTS: We observed lower values of latencies of wave I in the three rates of stimulus presentation and wave V at the rate of 21.7/sec. rarefact when used, and also on the right ear and the same polarity , the gap interpeak I - III also had lower values for rates of introduction, as in the IR range the rate of 21.7/s. In overall comparison of groups in different polarities of stimulation, there was a significant difference only in rarefact CONCLUSION: The understanding of the behavior of the electrophysiological response to variations of the stimulus is important and may serve as a reference for normal use of these measures in clinical practice...


Potencial evocado auditivo é uma resposta a um estímulo externo que representa a atividade eletrofisiológica do sistema auditivo em nível do tronco cerebral. Variações devido à alteração na apresentação de estímulos ajudam no diagnóstico de condições clínicas que afetam o sistema nervoso auditivo. : Caracterizar e comparar as diferentes variações de polaridade de estímulos e as taxas de apresentação em adultos com audição normal MÉTODO: foram investigados 20 estudantes de um centro de diagnóstico e de reabilitação, sem deficiência auditiva, todos do sexo feminino com idade de 15-30 anos de idade, que foram selecionados para potencial evocado auditivo de tronco cerebral, que apresentou estímulos em diferentes polaridades varia, incluindo a condensação e rarefação em diferentes taxas de apresentação de 21,7, 27,7 e 47,7 estímulos por segundo RESULTADOS: foram observados menores valores de latências da onda I nas três taxas de apresentação do estímulo e da onda V a uma taxa de 21,7 / seg. Em polaridade rarefeita, quando utilizado, e também sobre a orelha direita e a mesma polaridade, o fosso intérpico I - III tinha também apresentou valores mais baixos para as taxas, como na gama de IV a taxa de 21,7/s. Na comparação geral dos grupos em diferentes polaridades de estimulação houve diferença significativa apenas na polaridade rarefeita CONCLUSÃO: a compreensão do comportamento de resposta a variações eletrofisiológicas de estímulo é importante e pode servir como uma referência para o uso destas medidas na prática clínica...


Subject(s)
Humans , Male , Female , Auditory Cortex , Auditory Pathways , Evoked Potentials, Auditory , Evoked Potentials, Auditory, Brain Stem , Hearing Loss , Reference Values
2.
Arq. neuropsiquiatr ; 68(1): 87-92, Feb. 2010. tab
Article in English | LILACS | ID: lil-541195

ABSTRACT

Objective: To establish nerve conduction parameters for carpal tunnel syndrome (CTS) electrodiagnosis in the elderly. Method: Thirty healthy subjects (65-86 years), 9 male and 21 female, were studied. Routine median and ulnar sensory and motor nerve conduction studies, median mixed palmar latency, comparative latency techniques median to ulnar (sensory, mixed and motor lumbrical-interossei), median to radial (sensory), and combined sensory index (CSI) were performed in both hands. Results: The upper limits of normality (97.5 percent) were: median sensory distal latency 3.80 ms (14 cm); median motor distal latency 4.30 ms (8 cm); median palmar latency 2.45 ms (8 cm); lumbrical-interossei latency difference 0.60 ms (8 cm); comparative median to radial 0.95 ms (10 cm); comparative median to ulnar 0.95 ms (14 cm); comparative palmar median to ulnar 0.50 ms (8 cm); and CSI 2.20 ms. Sensory and mixed latencies were measured at peak. Conclusion: Our results establish new nerve conduction parameters for mild CTS electrodiagnosis in the elderly and will be helpful to reduce the number of false positive cases in this age.


Objetivo: Estabelecer parâmetros de condução nervosa para o eletrodiagnóstico da síndrome do túnel do carpo (STC) em idosos. Método: Foram estudadas 30 pessoas idosas (65-86 anos) saudáveis. Foi realizado estudo de condução nervosa sensitiva e motora rotineira dos nervos mediano e ulnar, latência palmar mista do mediano, técnicas de comparação de latências mediano-ulnar (sensitivo, misto e motor lumbrical-interósseo) e mediano-radial (sensitivo) e índice sensitivo combinado (ISC) em ambas as mãos. Resultados: Os limites superiores de normalidade, 97,5 por cento foram: latência distal sensitiva do mediano 3,80 ms (14 cm); latência distal motora do mediano 4,30 ms (8 cm), latência palmar do mediano 2,45 ms (8 cm), diferença de latência lumbrical-interósseo 0,60 ms (8 cm), comparação mediano-radial 0,95 ms (10 cm), comparação mediano-ulnar 0,95 ms (14 cm), comparação mediano-ulnar palmar 0,50 ms (8 cm) e ISC 2,20 ms. As latências sensitivas e mistas foram medidas no pico. Conclusão: Nossos resultados estabelecem novos valores de condução nervosa para o eletrodiagnóstico da STC leve em idosos.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Brachial Plexus/physiology , Carpal Tunnel Syndrome/diagnosis , Neural Conduction/physiology , Sural Nerve/physiology , Reference Values , Reaction Time/physiology
SELECTION OF CITATIONS
SEARCH DETAIL